Description: This machine is for Veterinary use only 12 Lead wireless Stress ECG system, ECG Workstation, CONTEC8000S Introduction The Stress ECG Analysis System is consist of sampling hardware device, special software system and exercise equipment. Its functions include 12 leads ECG synchronously sampling, and data storage, ST segment analysis, ECG review in dynamic/static/superimposed during the whole exercise process, and trend chart analysis of multiple parameters, multiple printable report, etc. The patient's exercise state can be recorded timely and accurately, which reflects patient’s heart function, providing reliable data for doctors in diagnoses. Features 1. Print ECG waveform in real-time during sampling process, record and save ECG data of whole process. 2. Observation of the changes of ST segment in real-time, enlargement display of user selected lead, automatic calculation of ST related data. 3. Adopt anti-interference technology to ensure the stabilization of baseline, reduce the effect on ECG waveform from EMG interference, baseline drift and AC interference. 4. Available for both standard and user-defined exercise scheme, automatic instantaneous notice of print and BP measure can be set according to exercise phrase. 5. Operator can mark events during exercise, the ECG waveform of marked event can be compared with current waveform. The event can be observed, edited and printed after excise. 6. Display and print of all kinds of trend chart. Mainly including: HR, BP, METS, HR*BP, exercise trend, ST segment level/influence/slope/3D/J level and ST/HR, etc. 7. Dynamic/static review function after exercise, representation of the whole exercise testing process. 8. Case Import/Export function. Compress the case for storage, which takes up less disk space. The compressed case shall be associated with the file type in operation system. This will make the import operation much more simple and quick. 9. System setting function includes multiple setting items. For example, switching Chinese/English language, format and mode of displaying waveform (12 leads * 1column / 6leads * 1column / 6leads * 2columns / 3leads * 2columns / 3 leads * 1column, etc), color of background, print related setting, filter setting and displaying of optional parameters, etc. 10. Provide multiple functional tools, which are used for device management, cases statistics and other operations. 11. Wireless mode of ECG data sampling, improves the anti-interference capability. 12. Supportive for variety types of exercise equipment Performance Patient leak current: <10µA Input impedance: ≥50MΩ Frequency response: 0.05Hz~150Hz (-3dB~+0.4dB) Time constant: ≥3.2s Common mode rejection ratio (CMRR):>60dB, >100dB (filter on) Calibration voltage: 1mV Sampling frequency: max. 1000 Hz Sampling accuracy: max. 24bits Input loop current: ≤50nA Polarization resistance voltage: ±500mV Noise level: ≤15µVp-p Safety type: internally powered equipment, type BF Accessories Wireless network card 1pc Lead cables 1pc Electrodes 1pc Grounding wire 1pc Velcro 2pcs Serial-port cable 1pc CD 1pc Software dog 1pc Serial-port card 1pc Physical Characteristic Dimension: 94mm(L) *66mm(W)*31mm(H) Weight: about 94.6g (without battery) Option configuration: Treadmill weight: 240kg (you need pay more,if you want to buy) Our software can connect with the following brand treadmill: § RAM 770 Italy § Track Master 425 USA § Paeha Korea § LODE VALIANT Netherlands Buy safe products The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved International Buyer--Please note: Import duties,Taxes are not included in the item price.These charges are buyers' responsibility We are the manufacturer of medical equipment for 17 years, the following are our main products: ECG / ECG holter EEG / EEG Holter B-ultrasound Patient Monitor Fetal doppler Fetal Monitor Spo2 Monitor Stethoscope Medical Image.... Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry? Join US! Skype:xuebox3 contec.med.mary at hotmail.com Only English User Manual,Please contact us if you need other language version.thank youThis product is sold worldwide, if you are using it in the United States, please contact me before purchasing
Price: 299 USD
Location: Qin huang dao
End Time: 2024-12-25T03:44:39.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Model: CONTEC8000S
Country/Region of Manufacture: China
MPN: 69450401
Brand: Con tec
Application: Stress Test